Desenho técnico
Características do artigo
- Utilization category
- DC
- Connection to output module
- Min. switching voltage at safety output
- Max. switching voltage at safety output
- Min. switching voltage at safety output
- Max. switching voltage at safety output
- Min. switching current at safety output
- Max. switching current at safety output
- Max. switching current at control output
- Response time
- Number of relay safety outputs
- Number of relay control outputs
- Feedback circuit
- Operating voltage min.
- Operating voltage max.
- Power consumption
- LED display
- PL acc. to EN ISO 13849-1
- SIL acc. to IEC 61508
- SIL CL acc. to IEC 62061
- PFHD according to IEC 61508
- Safe Failure Fraction (SFF) to IEC 61508
- Operating life
- Max no operating cycles at 1A switching current AC15 230V(B10d)
- Max no operating cycles at 2A switching current DC13 24V (B10d)
- Max no operating cycles at 3A switching current AC15 230V(B10d)
- Service life, mechanical (Cycles)
- Dimensions
- Housing material
- Housing colour
- Protection class, housing
- Operating temperature min.
- Max. operating temperature
- Min. storage temperature
- Max. storage temperature
- Relative humidity
- Mounting type
- Weight
- Torque for connection terminals
- Connection to base module
- Screw terminals
- Pluggable connection terminals
- Min. connection cross section
- Max. connection cross section
- Certified in accordance with
- CE label
Attribute | 485EPR02 | 485EPR04 | 485EPR04S08B |
---|---|---|---|
Bestellung |
|
|
|
Bestellung | |||
Utilization category | AC-15 / DC-13 | – | |
DC | Depending on the configuration % | ||
Connection to output module | – | via connection terminals | |
Min. switching voltage at safety output | 10 V DC | ||
Max. switching voltage at safety output | 250 V DC | ||
Min. switching voltage at safety output | 10 V AC | ||
Max. switching voltage at safety output | 400 V AC | 230 V AC | 400 V AC |
Min. switching current at safety output | 0.02 A | ||
Max. switching current at safety output | 6 A | ||
Max. switching current at control output | – | 0.1 A | |
Response time | 12 ms | ||
Number of relay safety outputs | 2 | 4 | |
Number of relay control outputs | – | 8 | |
Feedback circuit | yes | Depending on the configuration | |
Operating voltage min. | 19.2 V DC | ||
Operating voltage max. | 28.8 V DC | ||
Power consumption | 3 W | ||
LED display | single-coloured | No | |
PL acc. to EN ISO 13849-1 | e | ||
SIL acc. to IEC 61508 | 3 | ||
SIL CL acc. to IEC 62061 | 3 | ||
PFHD according to IEC 61508 | depending on the configuration 1/h | 1,30 x 10-9 1/h | |
Safe Failure Fraction (SFF) to IEC 61508 | – | 99.7 % | |
Operating life | 20 Tm | ||
Max no operating cycles at 1A switching current AC15 230V(B10d) | 750000 | – | |
Max no operating cycles at 2A switching current DC13 24V (B10d) | 10000000 | – | |
Max no operating cycles at 3A switching current AC15 230V(B10d) | 300000 | – | |
Service life, mechanical (Cycles) | > 20 x 10^6 | > 40 x 106 | |
Dimensions | 108 x 22,5 x 114,5 mm (H/B/T) | ||
Housing material | PA | ||
Housing colour | Gehaeuse schwarz Frontplatte gelb | ||
Protection class, housing | IP20 DIN EN 60529 | IP54 DIN EN 60529 | |
Operating temperature min. | -10 °C | ||
Max. operating temperature | 55 °C | ||
Min. storage temperature | -20 °C | ||
Max. storage temperature | 85 °C | ||
Relative humidity | 10...95 % | ||
Mounting type | Mounting rail | ||
Weight | 181 g | 231 g | 255 g |
Torque for connection terminals | 0.6 N m | ||
Connection to base module | via connection terminals | propriertary 5-way bus (T-connector) | |
Screw terminals | yes | ||
Pluggable connection terminals | yes | ||
Min. connection cross section | 0.5 mm² | ||
Max. connection cross section | 2.5 mm² | ||
Certified in accordance with | EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2 | – | |
CE label | yes |