Desenho técnico
Características do artigo
- Connection to base module
- Torque for connection terminals
- Max. switching voltage at safety output
- Max. switching voltage at control output
- Max. switching current at safety output
- Max. switching current at control output
- Number of configurable electronic safety outputs
- Number of electronic control outputs
- Number of test outputs (clocked)
- Number of safety inputs
- Stop category 0 (STO) nach IEC 61800-5-2
- Stop category 1 (SS1) nach IEC 61800-5-2
- EDM/start input
- Start function
- Feedback circuit
- Start-up test present
- Operating voltage min.
- Operating voltage max.
- Power consumption
- Wire-break detection
- Short-circuit detection
- Cross-short detection
- LED display
- Operating time
- Response time
- PL acc. to EN ISO 13849-1
- SIL acc. to IEC 61508
- SIL CL acc. to IEC 62061
- PFHD according to IEC 61508
- Safe Failure Fraction (SFF) to IEC 61508
- Operating life
- Category acc. to EN ISO 13849-1
- Dimensions
- Housing material
- Housing colour
- Protection class, housing
- Operating temperature min.
- Max. operating temperature
- Min. storage temperature
- Max. storage temperature
- Relative humidity
- Mounting type
- Weight
- Screw terminals
- Pluggable connection terminals
- Min. connection cross section
- Max. connection cross section
- Certified in accordance with
- CE label
Attribute | 485EPE08A02 |
---|---|
Bestellung |
|
Bestellung | |
Connection to base module | propriertary 5-way bus (T-connector) |
Torque for connection terminals | 0.6 N m |
Max. switching voltage at safety output | 24 V DC |
Max. switching voltage at control output | 24 V DC |
Max. switching current at safety output | 0.4 A |
Max. switching current at control output | 0.1 A |
Number of configurable electronic safety outputs | 2 |
Number of electronic control outputs | 2 |
Number of test outputs (clocked) | 8 |
Number of safety inputs | 8 |
Stop category 0 (STO) nach IEC 61800-5-2 | Depending on the configuration |
Stop category 1 (SS1) nach IEC 61800-5-2 | Depending on the configuration |
EDM/start input | Depending on the configuration |
Start function | Depending on the configuration |
Feedback circuit | Depending on the configuration |
Start-up test present | Depending on the configuration |
Operating voltage min. | 19.2 V DC |
Operating voltage max. | 28.8 V DC |
Power consumption | 3 W |
Wire-break detection | Depending on the configuration |
Short-circuit detection | Depending on the configuration |
Cross-short detection | Depending on the configuration |
LED display | four-coloured |
Operating time | Depending on the configuration ms |
Response time | in Bericht eP Safety Designer ms |
PL acc. to EN ISO 13849-1 | e |
SIL acc. to IEC 61508 | 3 |
SIL CL acc. to IEC 62061 | 3 |
PFHD according to IEC 61508 | 5,67 x 10-9 1/h |
Safe Failure Fraction (SFF) to IEC 61508 | 99.8 % |
Operating life | 20 Tm |
Category acc. to EN ISO 13849-1 | 4 |
Dimensions | 108 x 22,5 x 114,5 mm (H/B/T) |
Housing material | PA |
Housing colour | Gehaeuse schwarz Frontplatte gelb |
Protection class, housing | IP20 DIN EN 60529 |
Operating temperature min. | -10 °C |
Max. operating temperature | 55 °C |
Min. storage temperature | -20 °C |
Max. storage temperature | 85 °C |
Relative humidity | 10...95 % |
Mounting type | Mounting rail |
Weight | 185 g |
Screw terminals | yes |
Pluggable connection terminals | yes |
Min. connection cross section | 0.5 mm² |
Max. connection cross section | 2.5 mm² |
Certified in accordance with | EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2 |
CE label | yes |