Skip to content
Climate neutral since 2010

eloFlex Mini 470EFR…

eloFlex Mini 470EFR…

  • Up to 2 safety functions can be implemented in one device
  • The number of safety outputs (relays) can be set according to the individual requirement, making this a cost-effective solution
  • Increased functionality using less space in the switch cabinet
  • The units are tamper-proof as are pre-configured during ordering
  • Cost-effective and reliable by unique identification of configuration for maintenance, commissioning and service
  • Can be perfectly adapted to your application through various configuration options, offering maximum flexibility
  • Additional sensors can be connected via elobau interfaces for input expansion

 

The following logic and safety functions are available:

Logic link:

Safety functions:

ANDtON / tOFF
ORSafetyfunction
XOR2-hand
NANDSafetygate
NORE-stop
XNORN.O./N.O.
NOTor N.O./N.C.

eloFlex Mini 470EFR… is a configurable safety relay with 2 independent safety inputs (2-channel) and up to 2 safety outputs as well as 1 control output. The internal logic link is configured specifically for each customer.

Technical drawing

1/3
Cat_MS_SAE_470EFR_DRW1
Full screen
1/3
2/3
Cat_MS_SAE_470EFR_CON
Full screen
2/3
3/3
Cat_MS_SAE_470EFR_CD
Full screen
3/3

Article characteristics

  • 470EFR2D12K...
  • 470EFR3E11K...
  • 470EFR3E12K...
  • Max. switching voltage at safety output
  • Max. switching voltage at control output
  • Max. switching voltage at safety output
  • Max. switching current at safety output
  • Max. switching current at control output
  • Max. switching power at control output
  • Max. switching power at safety output
  • Number of configurable relay safety outputs
  • Number of electronic control outputs
  • Number of redundant safety inputs
  • Stop category 0 (STO) nach IEC 61800-5-2
  • Stop category 1 (SS1) nach IEC 61800-5-2
  • EDM/start input
  • Start function
  • Utilization category
  • Operating voltage min.
  • Operating voltage max.
  • Current consumption
  • Power consumption
  • Cross-short detection
  • LED display
  • Operating time
  • Overvoltage category
  • Min. switching voltage at safety output
  • Min. switching voltage at control output
  • Min. switching voltage at safety output
  • Min. switching current at safety output
  • Min. switching power at control output
  • Max. switching power at safety output
  • Min. switching power at safety output
  • Max no operating cycles at 0.5A switching current (ohmic load)
  • Max no operating cycles at 3A switching current (ohmic load)
  • Contact form
  • PL acc. to EN ISO 13849-1
  • SIL acc. to IEC 61508
  • SIL CL acc. to IEC 62061
  • PFHD according to IEC 61508
  • Operating life
  • Category acc. to EN ISO 13849-1
  • Hardware fault tolerance (HFT) according to IEC 61508
  • Dimensions
  • Housing material
  • Housing colour
  • Protection class
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
  • Relative humidity
  • Protection class, installation space
  • Shock resistance (Norm)
  • Continuous shock resistance (Norm)
  • Vibration resistance (Norm)
  • Air pressure
  • Delta tmax
  • Mounting type
  • Weight
  • Torque for connection terminals
  • Spring-type terminals
  • Screw terminals
  • Double terminals
  • Pluggable connection terminals
  • Min. connection cross section
  • Max. connection cross section
  • Certified in accordance with
  • CE label
Attribute470EFR2D12K...470EFR3E11K...470EFR3E12K...
Bestellung
Max. switching voltage at safety output 30 V DC
Max. switching voltage at control output 26.4 V DC
Max. switching voltage at safety output 250 V AC
Max. switching current at safety output 3 A
Max. switching current at control output 0.7 A
Max. switching power at control output 16.8 W
Max. switching power at safety output 750 VA
Number of configurable relay safety outputs 2 1 2
Number of electronic control outputs 2
Number of redundant safety inputs 2
Stop category 0 (STO) nach IEC 61800-5-2 yes
Stop category 1 (SS1) nach IEC 61800-5-2 yes
EDM/start input yes
Start function Depending on the configuration
Utilization category AC-15 / DC-13
Operating voltage min. 21.6 V DC
Operating voltage max. 26.4 V DC
Current consumption 200 mA
Power consumption 4.8 W
Cross-short detection yes
LED display two-coloured
Operating time 3000 ms
Overvoltage category II
Min. switching voltage at safety output 5 V DC
Min. switching voltage at control output 21.6 V DC
Min. switching voltage at safety output 5 V AC
Min. switching current at safety output 0.05 A
Min. switching power at control output 0.06 W
Max. switching power at safety output 90 W
Min. switching power at safety output 0.06 VA
Max no operating cycles at 0.5A switching current (ohmic load) 1000000 1500000
Max no operating cycles at 3A switching current (ohmic load) 190000 250000
Contact form Abhängig von der Konfiguration
PL acc. to EN ISO 13849-1 d e
SIL acc. to IEC 61508 2 3
SIL CL acc. to IEC 62061 2 3
PFHD according to IEC 61508 8,75x10^-8 1/h 3,86x10^-8 1/h
Operating life 20 Tm
Category acc. to EN ISO 13849-1 3 4
Hardware fault tolerance (HFT) according to IEC 61508 1
Dimensions 130 x 22,5 x 120 mm (H/B/T)
Housing material PA, PC
Housing colour schwarz
Protection class IP30 IEC60529
Operating temperature min. 0 °C
Max. operating temperature 55 °C
Min. storage temperature -40 °C
Max. storage temperature 70 °C
Relative humidity 5 - 85 %
Protection class, installation space IP55 IEC60529
Shock resistance (Norm) 30 g / 11 ms
Continuous shock resistance (Norm) 10 g / 16 ms
Vibration resistance (Norm) 10 ... 55 Hz
Air pressure 860 - 1060 hPa
Delta tmax 0.5 °C/min
Mounting type Mounting rail
Weight 200 g
Torque for connection terminals 0.5 N m
Spring-type terminals yes
Screw terminals Optional
Double terminals Optional
Pluggable connection terminals yes
Min. connection cross section 0.2 mm²
Max. connection cross section 2.5 mm²
Certified in accordance with EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2
CE label yes
Downloads
Manual safety control unit eloFlex 470EFR pdf 6.50 MB
Certificate_Tuev_Nord_eloFlex_Mini_998S0020_ZD1 pdf 585.57 KB
Certificate_Tuev_Nord_eloFlex_Mini_998S0020_ZE1 pdf 584.87 KB
Certificate_Tuev_Sued_eloFlex_Mini_Z10 020166 0057 Rev. 00 pdf 399.52 KB
UL certificate 470EFR eloFlex mini pdf 226.75 KB

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.

SPS 2024 – Smart Production Solutions

00
Days
00
Hours
00
minutes
00
Seconds