Skip to content
Climate neutral since 2010

Safety sensor eloProtect M 153MSK

Availabe in elostore

Safety sensor eloProtect M 153MSK

Availabe in elostore
  • Dual mounting options enables the door hinge to be mounted on the right or left (no extra variant necessary)
  • Available connection types: cable outlet and M12 pigtail
  • Simple diagnosis through optional LED and control contact
  • Screw covers prevent easy removal and the accumulation of dirt
  • Protection class IP6K9K (ISO 20653)

The eloProtect M series of sensors completely redefines the standard for magnetic safety sensors. eloProtect M offers increased operating distances and offset values for increased flexibility during installation and a high function stability. The new housing is robust and resistant to mechanical influences and aggressive media.

The safety sensor demonstrates strong resistance to cleaning agents (ECOLAB). The high IP6K9K protection class and the high temperature resistance of up to +80 °C make this ideal for use in the food and packaging industries as well as in the chemical and pharmaceutical industries.

This product is also available in the elo.store.

Technical drawing

1/4
Cat_MS_153_MSK_DRW1
Full screen
1/4
2/4
Cat_MS_153_MSK_CON
Full screen
2/4
3/4
Cat_MS_153_MSK_CD1
Full screen
3/4
4/4
Cat_MS_153_MSK_CD2
Full screen
4/4

Article characteristics

  • 153MSK00B1A
  • 153MSK00H1A
  • 153MSK00H1B
  • 153MSK00H1E
  • 153MSK00H1F
  • 153MSK00H1G
  • 153MSK00H1H
  • 153MSK00H1K
  • 153MSK00H1L
  • 153MSK00J1C
  • 153MSK00J1D
  • 153MSK00J1I
  • 153MSK00J1J
  • 153MSK00K1A
  • 153MSK00K1B
  • 153MSK00K1C
  • 153MSK00K1D
  • 153MSK00K1E
  • 153MSK00K1F
  • 153MSK00K1G
  • 153MSK00K1H
  • 153MSK00K1I
  • 153MSK00K1J
  • 153MSK00K1K
  • 153MSK00K1L
  • 153MSK10B1E
  • 153MSK10B1K
  • 153MSK10H1E
  • 153MSK10H1F
  • 153MSK10H1K
  • 153MSK10H1L
  • 153MSK10K1E
  • 153MSK10K1F
  • 153MSK10K1K
  • 153MSK10K1L
  • 153MSK00K1H31
  • 153MSK00B1G
  • 153MSK00B1E
  • 153MSK00B1K
  • 153MSK00B1F
  • 153MSK00B1L
  • 153MSK10B1F
  • 153MSK10B1L
  • Min. switching voltage
  • Max. switching voltage
  • Max. switching current
  • Max. switching current with LED
  • Max. switching power
  • Switching frequency
  • Assured switching distance (Sao)
  • Assured switch-off distance (Sar)
  • Minimum switching distance (S0 min)
  • LED display
  • Actuation
  • Switching principle
  • Series resistor
  • Technology
  • Contact form
  • Pollution degree
  • Protection class
  • Coding acc. to EN ISO 14119
  • B10d acc. to EN ISO 13849-1
  • Type acc. to EN ISO 14119
  • Mission time in years
  • Structure acc. to EN ISO 13849-1
  • Housing design
  • Dimensions
  • cannot be mounted flush
  • Detent present
  • Housing material
  • Cable material
  • Housing colour
  • Protection class
  • Protection class, connector
  • Operating temperature min.
  • Max. operating temperature
  • Min. cable temperature range, moving
  • Max. cable temperature range, moving
  • Min. cable temperature range, fixed installation
  • Max. cable temperature range, fixed installation
  • Shock resistance (Norm)
  • Vibration resistance (Norm)
  • Min. storage temperature
  • Max. storage temperature
  • Mounting type
  • Connector type
  • Cable length
  • Number of strands
  • Wire cross section
  • CE label
  • Certified in accordance with
  • Possible actuators
Attribute153MSK00B1A153MSK00H1A153MSK00H1B153MSK00H1E153MSK00H1F153MSK00H1G153MSK00H1H153MSK00H1K153MSK00H1L153MSK00J1C153MSK00J1D153MSK00J1I153MSK00J1J153MSK00K1A153MSK00K1B153MSK00K1C153MSK00K1D153MSK00K1E153MSK00K1F153MSK00K1G153MSK00K1H153MSK00K1I153MSK00K1J153MSK00K1K153MSK00K1L153MSK10B1E153MSK10B1K153MSK10H1E153MSK10H1F153MSK10H1K153MSK10H1L153MSK10K1E153MSK10K1F153MSK10K1K153MSK10K1L153MSK00K1H31153MSK00B1G153MSK00B1E153MSK00B1K153MSK00B1F153MSK00B1L153MSK10B1F153MSK10B1L
Bestellung
Min. switching voltage 19.2 V DC 19.2 V DC 19.2 V DC 19.2 V DC 19.2 V DC 19.2 V DC 19.2 V DC 19.2 V DC
Max. switching voltage 28.8 V DC 28.8 V DC 28.8 V DC 28.8 V DC 28.8 V DC 28.8 V DC 28.8 V DC 28.8 V DC
Max. switching current 0.2 A 0.2 A 0.2 A 0.2 A 0.2 A 0.2 A 0.2 A 0.2 A
Max. switching current with LED 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A
Max. switching power 3 W 3 W 3 W 3 W 3 W 3 W 3 W 3 W
Switching frequency 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz
Assured switching distance (Sao) 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm
Assured switch-off distance (Sar) 10 mm 10 mm 10 mm 10 mm 10 mm 17 mm 17 mm 10 mm 17 mm
Minimum switching distance (S0 min) 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 5 mm 5 mm 0.5 mm 5 mm
LED display No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured No single-coloured
Actuation front side front side front front side front side side front side
Switching principle magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic
Series resistor 10 Ohm 10 Ohm 10 Ohm 10 Ohm 10 Ohm 10 Ohm 10 Ohm 10 Ohm
Technology Reed Reed Reed Reed Reed Reed Reed Reed
Contact form NO/NO NO/NC NO/NO/NO (Kontrollkontakt) NO/NC/NO (Kontrollkontakt) NO/NO NO/NO/NO (Kontrollkontakt) NO/NO NO/NC NO/NC/NO (Kontrollkontakt) NO/NC NO/NO NO/NC NO/NO NO/NC NO/NO NO/NC NO/NO NO/NC NO/NO NO/NC NO/NO NO/NC NO/NO NO/NC
Pollution degree 3 3 3 3 3 3 3 3
Protection class III III III III III III III III
Coding acc. to EN ISO 14119 Low Low Low Low Low Low Low Low
B10d acc. to EN ISO 13849-1 20000000 20000000 20000000 20000000 20000000 20000000 20000000 20000000
Type acc. to EN ISO 14119 4 4 4 4 4 3 3 4 3
Mission time in years 20 a 20 a 20 a 20 a 20 a 20 a
Structure acc. to EN ISO 13849-1 Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel
Housing design rectangular rectangular rectangular rectangular rectangular rectangular rectangular rectangular
Dimensions 26 x 36 x 13 mm 26 x 36 x 13 mm 26 x 36 x 13 mm 26 x 36 x 13 mm 26 x 36 x 13 mm 26 x 36 x 13 mm 26 x 36 x 13 mm 26 x 36 x 13 mm
cannot be mounted flush yes yes yes yes yes yes yes yes
Detent present no no no no no no no no
Housing material PBT, PC PBT, PC PBT, PC PBT, PC PBT, PC PBT, PC PBT, PC PBT, PC
Cable material PVC PVC PVC PVC PVC PVC PVC PVC
Housing colour grau, schwarz grau, schwarz grau, schwarz grau, schwarz grau, schwarz grau, schwarz grau, schwarz grau, schwarz
Protection class IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653
Protection class, connector IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529
Operating temperature min. -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C
Max. operating temperature 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C
Min. cable temperature range, moving -5 °C -5 °C -5 °C -5 °C -5 °C -5 °C -5 °C -5 °C
Max. cable temperature range, moving 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C
Min. cable temperature range, fixed installation -30 °C -30 °C -30 °C -30 °C -30 °C -30 °C -30 °C -30 °C
Max. cable temperature range, fixed installation 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C
Shock resistance (Norm) 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms
Vibration resistance (Norm) 10 - 55Hz 10 - 55Hz 10 - 55Hz 10 - 55Hz 10 - 55Hz 10 - 55Hz 10 - 55Hz 10 - 55Hz
Min. storage temperature -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -28 °C -25 °C
Max. storage temperature 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C
Mounting type screwed screwed screwed screwed screwed screwed screwed screwed
Connector type M8x1 - 4 polig M12x1 - 4 polig M12x1 - 4 polig M12x1 - 8 polig M8x1 - 4 polig M12x1 - 4 polig M12x1 - 8 polig M8x1 - 4 polig M12x1 - 4 polig
Cable length 0.15 m 0.15 m 0.15 m 1 m 1 m 0.15 m 1 m 0.15 m 1 m 0.15 m
Number of strands 4 4 8 4 6 4 6 4 4 4 4
Wire cross section 0.25 mm² 0.25 mm² 0.25 mm² 0.25 mm² 0.25 mm² 0.25 mm² 0.25 mm² 0.25 mm²
CE label yes yes yes yes yes yes yes yes
Certified in accordance with UL UL UL UL UL UL UL UL
Possible actuators 153MBK001 153MBK001 153MBK001 153MBK001 153MBK001 153MBK101 153MBK101 153MBK001 153MBK101
1/3
153MSK_switching-distance
Full screen
1/3
2/3
Safety sensor eloProtect M 153MSK | IP6K9K | elobau
Full screen
2/3
3/3
Safety sensor eloProtect M 153MSK | IP6K9K | elobau
Full screen
3/3
Manual safety sensor eloProtect M 153MSK
Manual eloProtect M - Safety sensor series 153MSK... pdf 2.08 MB
Certificate eloProtect MSK - TÜV Süd pdf 1,001.13 KB
Certificate eloProtect MSK (EC-Type Examination) - TÜV Süd pdf 903.40 KB

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.

SPS 2024 – Smart Production Solutions

00
Days
00
Hours
00
minutes
00
Seconds