Skip to content
Climate neutral since 2010

eloFlex 471EFR…

Star Star Star Star Star (1) Rate this product

eloFlex 471EFR…

Star Star Star Star Star (1) Rate this product
  • Up to 4 safety functions can be implemented in one device
  • The number of safety outputs (relays) can be set according to the individual requirement, making this a cost-effective solution.
  • Increased functionality using less space in the switch cabinet.
  • The units are tamper-proof as are pre-configured during ordering.
  • Cost-effective and reliable by unique identification of configuration for maintenance, commissioning and service
  • Can be perfectly adapted to your application through various configuration options, offering maximum flexibility
  • Additional sensors can be connected via elobau interfaces for input expansion

 

The following logic and safety functions are available:

Logic link:

Safety functions:

ANDtON / tOFF
ORSafetyfunction
XOR2-hand
NANDSafetygate
NORE-stop
XNORN.O./N.O.
NOTor N.O./N.C.

eloFlex 471 EFR… is a configurable safety relay with 4 independent safety inputs (2-channel) and up to 4  safety outputs as well as 4 control outputs.

The internal logic link is configured specifically for each customer.

Technical drawing

1/4
Cat_MS_SAE_471EFR_DRW1
Full screen
1/4
2/4
Cat_MS_SAE_471EFR_CON
Full screen
2/4
3/4
Cat_MS_SAE_471EFR_CD1
Full screen
3/4
4/4
Cat_MS_SAE_471EFR_CD2
Full screen
4/4

Article characteristics

  • 471EFR2D14K...
  • 471EFR3E11K...
  • 471EFR3E12K...
  • 471EFR3E13K...
  • 471EFR3E14K...
  • 471EFR3E11K_
  • 471EFR3E12K_
  • 471EFR3E13K_
  • 471EFR3E14K_
  • 471EFR2D14K_
  • Max. switching voltage at safety output
  • Max. switching voltage at control output
  • Max. switching voltage at safety output
  • Max. switching current at safety output
  • Max. switching current at control output
  • Max. switching power at control output
  • Max. switching power at safety output
  • Number of configurable relay safety outputs
  • Number of electronic control outputs
  • Number of redundant safety inputs
  • Stop category 0 (STO) nach IEC 61800-5-2
  • Stop category 1 (SS1) nach IEC 61800-5-2
  • EDM/start input
  • Start function
  • Utilization category
  • Operating voltage min.
  • Operating voltage max.
  • Current consumption
  • Power consumption
  • Cross-short detection
  • LED display
  • Operating time
  • Fuse operating voltage
  • Overvoltage category
  • Fuse safety output
  • Min. switching voltage at control output
  • Max. switching power at safety output
  • Max no operating cycles at 0.5A switching current (ohmic load)
  • Max no operating cycles at 3A switching current (ohmic load)
  • Contact form
  • PL acc. to EN ISO 13849-1
  • SIL acc. to IEC 61508
  • SIL CL acc. to IEC 62061
  • PFHD according to IEC 61508
  • Operating life
  • Category acc. to EN ISO 13849-1
  • Hardware fault tolerance (HFT) according to IEC 61508
  • Max. switching frequency safety output with load
  • Max. switching frequency safety output with load
  • Dimensions
  • Housing material
  • Housing colour
  • Protection class
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
  • Relative humidity
  • Protection class, installation space
  • Shock resistance (Norm)
  • Continuous shock resistance (Norm)
  • Vibration resistance (Norm)
  • Air pressure
  • Delta tmax
  • Mounting type
  • Weight
  • Torque for connection terminals
  • Spring-type terminals
  • Screw terminals
  • Double terminals
  • Pluggable connection terminals
  • Min. connection cross section
  • Max. connection cross section
  • Certified in accordance with
  • CE label
Attribute471EFR2D14K...471EFR3E11K...471EFR3E12K...471EFR3E13K...471EFR3E14K...471EFR3E11K_471EFR3E12K_471EFR3E13K_471EFR3E14K_471EFR2D14K_
Bestellung
Max. switching voltage at safety output 30 V DC 30 V DC
Max. switching voltage at control output 26.4 V DC 26.4 V DC
Max. switching voltage at safety output 250 V AC 250 V AC
Max. switching current at safety output 3 A 3 A
Max. switching current at control output 0.1 A 0.1 A
Max. switching power at control output 2.64 W 2.64 W
Max. switching power at safety output 750 VA 750 VA
Number of configurable relay safety outputs 4 1 2 3 4 1 2 3 4
Number of electronic control outputs 4 4
Number of redundant safety inputs 4 4
Stop category 0 (STO) nach IEC 61800-5-2 yes yes
Stop category 1 (SS1) nach IEC 61800-5-2 yes yes
EDM/start input yes yes
Start function Depending on the configuration Depending on the configuration
Utilization category AC-15 / DC-13 AC-15 / DC-13
Operating voltage min. 21.6 V DC 21.6 V DC
Operating voltage max. 26.4 V DC 26.4 V DC
Current consumption 800 mA 800 mA
Power consumption 21.12 W 21.12 W
Cross-short detection yes yes
LED display two-coloured two-coloured
Operating time 3000 ms 3000 ms
Fuse operating voltage 1A fast 1A fast
Overvoltage category III III
Fuse safety output 3A slow blow 3A slow blow
Min. switching voltage at control output 21.6 V DC 21.6 V DC
Max. switching power at safety output 90 W 90 W
Max no operating cycles at 0.5A switching current (ohmic load) 1000000 3000000 3000000 1000000
Max no operating cycles at 3A switching current (ohmic load) 190000 280000 280000 190000
Contact form Abhängig von der Konfiguration Abhängig von der Konfiguration
PL acc. to EN ISO 13849-1 d e e d
SIL acc. to IEC 61508 2 3 3 2
SIL CL acc. to IEC 62061 2 3 3 2
PFHD according to IEC 61508 1,26x10^-8 1/h 3,28x10^-9 1/h 3,28x10^-9 1/h 1,26x10^-8 1/h
Operating life 20 Tm 20 Tm
Category acc. to EN ISO 13849-1 3 4 4 3
Hardware fault tolerance (HFT) according to IEC 61508 1 1
Max. switching frequency safety output with load 360 1/h 360 1/h
Max. switching frequency safety output with load 72000 1/h 18000 1/h 18000 1/h 72000 1/h
Dimensions 130 x 45 x 120 mm (H/B/T) 130 x 45 x 120 mm (H/B/T)
Housing material PA, PC PA, PC
Housing colour schwarz schwarz
Protection class IP30 IEC60529 IP30 IEC60529
Operating temperature min. -15 °C -15 °C
Max. operating temperature 55 °C 55 °C
Min. storage temperature -40 °C -25 °C -25 °C -40 °C
Max. storage temperature 70 °C 70 °C
Relative humidity 5 - 85 % 5 - 85 %
Protection class, installation space IP54 DIN EN 60529 IP54 DIN EN 60529
Shock resistance (Norm) 30 g / 11 ms 30 g / 11 ms
Continuous shock resistance (Norm) 10 g / 16 ms 10 g / 16 ms
Vibration resistance (Norm) 10 ... 55 Hz 10 ... 55 Hz
Air pressure 860 - 1060 hPa 860 - 1060 hPa
Delta tmax 0.5 °C/min 0.5 °C/min
Mounting type Mounting rail Mounting rail
Weight 400 g 400 g
Torque for connection terminals 0.5 N m 0.5 N m
Spring-type terminals yes yes
Screw terminals Optional Optional
Double terminals Optional Optional
Pluggable connection terminals yes yes
Min. connection cross section 0.2 mm² 0.2 mm²
Max. connection cross section 2.5 mm² 2.5 mm²
Certified in accordance with EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2 EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2
CE label yes yes
1/1
471EFR_configuration
Full screen
1/1
Downloads
Manual Safety Control Unit eloFlex 471EFR pdf 2.77 MB
Certificate eloFlex 471EFR - TÜV Süd pdf 720.54 KB
Certificate eloFlex 471EFR (EC-Type Examination) - TÜV Süd pdf 698.97 KB
Certificate eloFlex 471EFR - UL pdf 682.99 KB
Certificate eloFlex 471EFR - CSA pdf 668.84 KB

Customer reviews

Star Star Star Star Star

4 out of 6 customers find this rating helpful.

SAKTHI K., POPPYS KNITWEAR PVT LTD, 27.11.2019
Evaluated article: eloFlex 471EFR...

Did you find this evaluation helpful?

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.

SPS 2024 – Smart Production Solutions

00
Days
00
Hours
00
minutes
00
Seconds